Kuttiyadi Hydroelectric Project

Kuttiyadi Hydro Electric Project was completed and commissioned in the year 1972. The project is located at Kuttiyadi dam, at Kuttiyadi River. The kuttiyadi dam is situated at Peruvannamuzhi, approximately 60 Km from Kozhikode, Kerala, India. This is a major type project and the total installed capacity of the project is 225 MW. This is a dam shaped structure and the power house is a surface type. The project is currently in operational situation. This is a storage type hydroelectric project and the seismic zone is zone III. The project is owned by the Kerala government and comes under the Kerala State Electricity Board (KSEB). The project has 6 turbines and all the turbines are in pelton shape. Out of the 6 turbines, 3 turbines has a capacity of 25 MW and the other 3 has a capacity of 50 MW. The turbine and generator manufacturers of the project are Fuji Japan for units 1, 2 and 3. VA Tech Hydro is the manufacturers for unit 4 and BHEL is for units 5 and 6. The project has 6 numbers of commissioned units and 1 penstock. The length of the penstock is 2083 meters. West flowing rivers are the hydroelectric basin of the project and the hydroelectric region of the project is south hydroelectric region. The project is mainly used for hydroelectric power generation.


Hydroelectric Project Details

 

Salient Features

 

Name of Power Project

 

Kuttiyadi Hydroelectric Project

Name of Power House

 

Kuttiyadi Power House

Commission Year

 

1972

Type of Project

 

Major (greater than 25 MW)

Type of Powerhouse

 

Surface

Type of Structure

 

Dam

Power House Position

 

Others

Project Status

 

Operational

River

 

Kuttiyadi River

Hydroelectric Basin

 

West flowing Rivers

Hydroelectric Region

 

South Hydroelectric Region

Seismic Zone

 

Zone III

Hydroelectric Development Type

Storage


Owner of Power Plant

 

Kerala Government

Owner Name

 

Kerala State Electricity Board (KSEB)

Location

 

Peruvannamuzhi

District

 

Kozhikode

State

 

Kerala

Country

 

India

Office Phone

 

+91 (471) 244 6480

Email Id

 

-

Web Address

 

www.kseb.in

Completion Year

 

1972

Total no: of Turbines

 

6

Capacity per Turbine in MW

 

3 x 25 MW & 3 x 50 MW

Total Installed Capacity

 

225 MegaWatt

Turbine Type

 

Pelton

Turbine Maker

 

Unit 1, 2 & 3 - Fuji Japan, Unit 4 - VA Tech Hydro, Unit 5, 6 - BHEL

Generator Maker

 

Unit 1, 2 & 3 - Fuji Japan, Unit 4 - VA Tech Hydro, Unit 5, 6 - BHEL

Total Units and Size

 

3 units x 25 MW (75 MW), 3 units x 50 MW (150 MW)

No of Commissioned Units

6

 

Number of Penstock

 

1

Length of Penstock

 

2083 m

Purpose

 

Hydroelectric Power Generation

 