Kakkad Hydroelectric Project

Kakkad hydro electric project was commissioned in the year 1998 and completed in the year 1999. This is one of the major power house projects across Veluthodu, Moozhiyoor, Pamba. It is an operational Dam structure lying in zone 3 of the Indian seismic zone. The basin of this dam is west flowing rivers and comes under south hydroelectric region. It is a storage type of hydroelectric development. This power plant is owned by kerala government and is operated by kerala State Electricity Board (KSEB). Location of the dam is Seethathodu, Pathanamthitta, Kerala, India. The total number of turbines is two and capacity of each turbine is 25 megawatt making the total installed capacity to 50 megawatt. The type of turbine used is Francis turbine. Both turbine and generator manufacturer of project is Bharat Heavy Electrical Limited, India. There are total two units of 25 megawatt each making it 50 megawatt. There are two commissioned units with two penstocks each having 25m length. The purpose of this project is hydroelectric power generation. Water flowing through the turbines is 45.16 cumecs. The altitude of the reservoir above mean sea level is at a maximum of 192.6 and minimum of 181.36m. The name of the dam is Moozhiyar Sabarigiri Dam. The configuration of powerhouse is one surface powerhouse. Power production potential at design is 262 GW hours per year at water head of 132.6m.  Capacity of main reservoir at FRL is 1.16 mm cumec. This power plant is used for base load.


Hydroelectric Project Details

Salient Features

Name of Power Project

Kakkad Hydroelectric Project
Name of Power House

Kakkad Power House
Commission Year

1998
Type of Project

Major
Type of Powerhouse

Surface
Type of Structure

Dam
Power House Position

Others
Project Status

Operational
River

Veluthodu, Moozhiyar, Pamba
Hydroelectric Basin

West flowing Rivers
Hydroelectric Region

South Hydroelectric Region
Seismic Zone

Zone III
Hydroelectric Development Type

Storage
Owner of Power Plant

Kerala Government
Owner Name

Kerala State Electricity Board (KSEB)
Location

Seethathodu
District

Pathanamthitta
State

Kerala
Country

India
Office Phone

+91 (471) 244 6480
Email Id

-
Web Address

www.kseb.in
Completion Year

1999
Total no: of Turbines

2
Capacity per Turbine in MW

25 MW
Total Installed Capacity

50 Megawatt
Turbine Type

Francis
Turbine Maker

BHEL India
Generator Maker

BHEL India
Total Units and Size

2 units x 25 MW (50 MW)
No of Commissioned Units

2
Number of Penstock

2
Length of Penstock

25 m
Purpose

Hydroelectric Power Generation